PH sensor

PH sensor
WPH1007

Features

Flue gas desulfurization (FGD) and other severe environments like whitewash, seriflux, etc. can be measured for pH using the WPH1007 Flat pH electrode. An excellent sensor for measuring and analyzing liquid components during industrial automation is the pH electrode. These electrodes are renowned for using premium components and materials. The measuring electrode and the reference electrode are integrated into a single shaft in their design as combined electrodes.As an alternative, the temperature probe can also be included.

pH Calibration

Enter the PH calibration screen, the first PH electrode intothe4.00PH standard solution, standing for a moment, to be stable after the show, press the ENT, then the PH electrode into the 6.86PH standard solution Set the PH electrode into the 9.18PH standard solution, put it aside for a moment, after the test is stable, press ENT, the display shows the success of the calibration, the whole process of PH calibration complete

Technical Specification

Product
Flat pH sensor
Model
WPH1007
Measurement range
2~12pH
Temperature
0~60℃
Pressure range
0.4MPa
Temperature compensation
NTC10K/PT100/PT1000
Reference structure
Teflon ring/doubleliquid junction
Thread Connection
3/4NPT
Shell material
PPS
Slope
(PTS values) ≧95% (25℃)
Resistance
≦250 mΩ

Sensors

Features

Compact structure and easy installation
Isolated power supply design, data
stability, strong anti-interference ability
automatic/manual temperature
compensation
Automatically detect whether the
temperature probe is disconnected or
faulty, then switch to manual
temperature compensation
Support USA/NIST/custom pH calibration
solution, and user-defined ORP standard
solution
Communication: RS485 interface*1
(Modbus RTU protocol)

The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument.The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. WKP100 is a digital sensor with RS485 designed by our company for the aquiculture industry, which can be used to measure the change of pH/ORP value in an aqueous solution system within the range. The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communication Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations.

Applications

Accessories

Documents

    At WellKonix, we are dedicated to delivering innovative, technology-driven solutions tailored to your needs. Our focus on quality, efficiency, and excellence ensures that you receive the best products and services that drive measurable results.

    WellKonix is a leading solutions provider, bringing advanced technologies and expertise across various sectors.

    ADDRESS

    Prestebråtan 21 3300 Hokksund Norway

    PHONE

    +1 (0) 345 678 9

    EMAIL

    info@wellkonix.com

    Cart